// DialTimerTaskMeasu.cpp : implementation file
|
|
//
|
|
|
|
#include "stdafx.h"
|
|
#include "geomative.h"
|
|
#include "DialTimerTaskMeasu.h"
|
|
#include "OperPLC.h"
|
|
#include "FileOperTools.h"
|
|
#include "DialTimerTask.h"
|
|
#include "Lock/AutoLock.h"
|
|
#ifdef _DEBUG
|
|
#define new DEBUG_NEW
|
|
#undef THIS_FILE
|
|
static char THIS_FILE[] = __FILE__;
|
|
#endif
|
|
|
|
/////////////////////////////////////////////////////////////////////////////
|
|
// CDialTimerTaskMeasu dialog
|
|
#define MAX_TIMER_REPEAT_SND_CNT 90000
|
|
#define MODULE_NAME "CDialTimerTaskMeasu"
|
|
#define MAX_TIMER_LIST_SHOW 25
|
|
extern CGeoMativeApp theApp;
|
|
extern SYSTEMTIME g_sysCurTime;
|
|
extern void SplitterString(CStringArray &szArray,const CString& szSource, const CString& szSplitter);
|
|
extern int g_iUILanguage;
|
|
extern float tcp_ntohf(float f);
|
|
extern float tcp_htonf(float f);
|
|
extern CString GetMeasuStatusByAlarm(BYTE ucAlarm);
|
|
CDialTimerTaskMeasu::CDialTimerTaskMeasu(CWnd* pParent /*=NULL*/)
|
|
: CDialog(CDialTimerTaskMeasu::IDD, pParent)
|
|
{
|
|
//{{AFX_DATA_INIT(CDialTimerTaskMeasu)
|
|
// NOTE: the ClassWizard will add member initialization here
|
|
//}}AFX_DATA_INIT
|
|
m_bIsSigMeasuring = false;
|
|
m_iRepeatSndCnt = -1;
|
|
m_vtMeasureData.clear();
|
|
m_bIsRunning = false;
|
|
m_pThread = NULL;
|
|
m_bIsThreadFinshed = true;
|
|
m_bIsOpenTbData = false;
|
|
m_ucCmd = 0;
|
|
memset(m_ucData, 0, sizeof(m_ucData));
|
|
m_iRecvDataLen = 0;
|
|
m_bIsSuspend = false;
|
|
m_uiDevID = 0;
|
|
m_ucCmd = 0;
|
|
m_bIsThreadFinshed = true;
|
|
|
|
}
|
|
|
|
|
|
void CDialTimerTaskMeasu::DoDataExchange(CDataExchange* pDX)
|
|
{
|
|
CDialog::DoDataExchange(pDX);
|
|
//{{AFX_DATA_MAP(CDialTimerTaskMeasu)
|
|
DDX_Control(pDX, IDC_LIST_MEASU_DATA, m_listMeasuData);
|
|
//}}AFX_DATA_MAP
|
|
}
|
|
|
|
|
|
BEGIN_MESSAGE_MAP(CDialTimerTaskMeasu, CDialog)
|
|
//{{AFX_MSG_MAP(CDialTimerTaskMeasu)
|
|
ON_BN_CLICKED(IDC_BUTTON_TIMER_MRASU, OnButtonTimerMeasu)
|
|
ON_BN_CLICKED(IDC_BUTTON_MRASU_SUSPEND, OnButtonMrasuSuspend)
|
|
ON_BN_CLICKED(IDC_BUTTON_TIMER_CFG, OnButtonTimerCfg)
|
|
//}}AFX_MSG_MAP
|
|
END_MESSAGE_MAP()
|
|
|
|
/////////////////////////////////////////////////////////////////////////////
|
|
// CDialTimerTaskMeasu message handlers
|
|
|
|
void CDialTimerTaskMeasu::OnButtonTimerMeasu()
|
|
{
|
|
// TODO: Add your control notification handler code here
|
|
if (!m_bIsThreadFinshed)
|
|
{
|
|
if (LANG_ZHCN == g_iUILanguage)
|
|
AfxMessageBox(_T("请不要重复测量"));
|
|
else
|
|
MessageBoxEx(NULL, _T("Please do not repeat measure."), STRING_MESSAGEBOXEX_TITLE, MB_OK, MAKELANGID(LANG_ENGLISH, SUBLANG_ENGLISH_US));
|
|
return;
|
|
}
|
|
if (NULL == m_pThread)
|
|
{
|
|
m_bIsRunning = true;
|
|
m_pThread = AfxBeginThread(StartMeasuData,(LPVOID)this);
|
|
if (NULL == m_pThread)
|
|
{
|
|
m_bIsRunning = false;
|
|
if (LANG_ZHCN == g_iUILanguage)
|
|
AfxMessageBox(_T("创建处理数据线程失败"));
|
|
else
|
|
MessageBoxEx(NULL, _T("Create process data thread failed."), STRING_MESSAGEBOXEX_TITLE, MB_OK, MAKELANGID(LANG_ENGLISH, SUBLANG_ENGLISH_US));
|
|
return ;
|
|
}
|
|
GetDlgItem(IDC_BUTTON_TIMER_MRASU)->EnableWindow(FALSE);
|
|
}
|
|
|
|
|
|
|
|
}
|
|
|
|
void CDialTimerTaskMeasu::OnButtonMrasuSuspend()
|
|
{
|
|
// TODO: Add your control notification handler code here
|
|
if (!m_bIsSuspend)
|
|
{
|
|
m_bIsSuspend = true;
|
|
SetBtnStatus(EN_TIMER_PROC_MEASU_SUSPEND);
|
|
}
|
|
else
|
|
{
|
|
m_bIsSuspend = false;
|
|
SetBtnStatus(EN_TIMER_PROC_MEASU_CONTINUE);
|
|
}
|
|
|
|
}
|
|
|
|
void CDialTimerTaskMeasu::ThreadJoin()
|
|
{
|
|
if (NULL == m_pThread)
|
|
{
|
|
return;
|
|
}
|
|
m_bIsRunning = false;
|
|
Sleep(100);
|
|
bool bIsShow = false;
|
|
while(!m_bIsThreadFinshed)
|
|
{
|
|
Sleep(100);
|
|
}
|
|
}
|
|
|
|
bool CDialTimerTaskMeasu::ProcRcvMeasuData()
|
|
{
|
|
CString strErr;
|
|
if (m_iRecvDataLen < 1)
|
|
{
|
|
strErr.Empty();
|
|
strErr.Format(_T("[%s][%d]接收数据错误,接收字节数不能小于1"),MODULE_NAME, __LINE__);
|
|
CFileOperTools::GetInstance()->WriteComLog(strErr);
|
|
return EN_MEASU_PROC_DATA_ERR;
|
|
}
|
|
BYTE ucPacketNum = *((BYTE*)m_ucData + sizeof(m_stQueryTdInfo.ucTaskID));
|
|
|
|
if (ucPacketNum != m_vtMeasureData.size())
|
|
{
|
|
strErr.Empty();
|
|
strErr.Format(_T("[%s][%d]测量数据包数目错误,本该测量包数=%d,实测包数=%d"), MODULE_NAME, __LINE__,m_vtMeasureData.size(),ucPacketNum);
|
|
CFileOperTools::GetInstance()->WriteComLog(strErr);
|
|
return EN_MEASU_PROC_DATA_ERR;
|
|
}
|
|
LPSTMeasuBasicDataRes pMeasuBasicRes = NULL;
|
|
int iAttachLen = (1 == m_stQueryTdInfo.iTestType) ? sizeof(STMeasuDataResAttachIP) : 0;
|
|
//这里暂时没有对粘包或者分包做处理
|
|
if (m_iRecvDataLen != (1 + sizeof(m_stQueryTdInfo.ucTaskID) + ucPacketNum*(sizeof(STMeasuDataResBasic)+iAttachLen)))
|
|
{
|
|
strErr.Empty();
|
|
strErr.Format(_T("[%s][%d]测量数据包长度错误,本该=%d,实际长度=%d"), MODULE_NAME, __LINE__, 1+sizeof(m_stQueryTdInfo.ucTaskID)+ucPacketNum*(sizeof(STMeasuDataResBasic)+iAttachLen), m_iRecvDataLen);
|
|
CFileOperTools::GetInstance()->WriteComLog(strErr);
|
|
return EN_MEASU_PROC_DATA_ERR;
|
|
}
|
|
for (int i = 0; i < ucPacketNum; i++)
|
|
{
|
|
pMeasuBasicRes = (LPSTMeasuBasicDataRes)(m_ucData + 1 + sizeof(m_stQueryTdInfo.ucTaskID) + i*(sizeof(STMeasuDataResBasic)+iAttachLen));
|
|
pMeasuBasicRes->iID = ntohl(pMeasuBasicRes->iID);//by quyx 20180902
|
|
if (pMeasuBasicRes->iID != m_vtMeasureData[i].dwTsn)
|
|
{
|
|
strErr.Empty();
|
|
strErr.Format(_T("[%s][%d]测量数据乱序,测量TSN(%d),实际接收数据的TSN(%d)"),MODULE_NAME, __LINE__, m_vtMeasureData[i].dwTsn, pMeasuBasicRes->iID);
|
|
CFileOperTools::GetInstance()->WriteComLog(strErr);
|
|
return EN_MEASU_PROC_DATA_ERR;
|
|
}
|
|
//处理告警
|
|
CString strMeasuStaus = _T("");
|
|
if (LANG_ZHCN == g_iUILanguage)
|
|
strMeasuStaus.Format(_T("测量状态: %s"), GetMeasuStatusByAlarm(pMeasuBasicRes->ucAlram));
|
|
else
|
|
strMeasuStaus.Format(_T("Status: %s"), GetMeasuStatusByAlarm(pMeasuBasicRes->ucAlram));
|
|
|
|
GetDlgItem(IDC_STATIC_ALARM)->SetWindowText(strMeasuStaus);
|
|
//如果碰到下面告警,则测量必须要停下来
|
|
// if ((pMeasuBasicRes->ucAlram > 0 && pMeasuBasicRes->ucAlram < 3) ||
|
|
// (pMeasuBasicRes->ucAlram > 3 && pMeasuBasicRes->ucAlram < 7))
|
|
//modifyed by lsq 20171019 这里应张杰的要求,修改临时版本,允许过流保护和短路保护时,继续测量
|
|
if (2 == pMeasuBasicRes->ucAlram)
|
|
{
|
|
if (LANG_ZHCN == g_iUILanguage)
|
|
AfxMessageBox(_T("遇到严重告警,终止测量"));
|
|
else
|
|
MessageBoxEx(NULL, _T("Stop measuring if severe warning is encountered"), STRING_MESSAGEBOXEX_TITLE, MB_OK, MAKELANGID(LANG_ENGLISH, SUBLANG_ENGLISH_US));
|
|
|
|
return EN_MEASU_PROC_WARINNG;
|
|
}
|
|
//网络序转本机序 by quyx 20180902
|
|
pMeasuBasicRes->fI = tcp_ntohf(pMeasuBasicRes->fI);
|
|
pMeasuBasicRes->fK = tcp_ntohf(pMeasuBasicRes->fK);
|
|
pMeasuBasicRes->fR0 = tcp_ntohf(pMeasuBasicRes->fR0);
|
|
pMeasuBasicRes->fR0_LC = tcp_ntohf(pMeasuBasicRes->fR0_LC);
|
|
pMeasuBasicRes->fSP = tcp_ntohf(pMeasuBasicRes->fSP);
|
|
pMeasuBasicRes->fV = tcp_ntohf(pMeasuBasicRes->fV);
|
|
if (m_TaskdDBOper.UpdateTdBasicData(m_stQueryTdInfo.iSptType, m_stQueryTdInfo.iTestType,m_stQueryTdInfo.iTdChannelID,
|
|
m_vtMeasureData[i].dwTsn, pMeasuBasicRes, m_ucData + 1 + sizeof(m_stQueryTdInfo.ucTaskID) + (i + 1)*sizeof(STMeasuDataResBasic)+i*iAttachLen))
|
|
{
|
|
// m_iListDataID++;
|
|
bool bIsNeedInsert = true;
|
|
int iItemIndex;
|
|
// if (m_iSelMeasuIndex>=0 && m_iSelMeasuIndex < m_dialListMeasuTask.m_listData.GetItemCount() )
|
|
// {
|
|
// iItemIndex = m_iSelMeasuIndex++;
|
|
// bIsNeedInsert = false;
|
|
// }
|
|
// else
|
|
// {
|
|
// m_iSelMeasuIndex = -1;
|
|
if (m_listMeasuData.GetItemCount() >= MAX_TIMER_LIST_SHOW)
|
|
m_listMeasuData.DeleteAllItems();
|
|
iItemIndex = m_listMeasuData.GetItemCount();
|
|
// }
|
|
CString strTxt = _T("");
|
|
|
|
|
|
// if (bIsNeedInsert)
|
|
// {
|
|
strTxt.Empty();
|
|
strTxt.Format(_T("%d"), m_vtMeasureData[i].dwTsn);
|
|
m_listMeasuData.InsertItem(iItemIndex,strTxt);
|
|
// }
|
|
|
|
|
|
int iColIndex = 1;
|
|
strTxt.Empty();
|
|
if (0 == m_stQueryTdInfo.iSptType)
|
|
strTxt.Format(_T("%.2f"), m_vtMeasureData[i].fA);
|
|
else
|
|
strTxt.Format(_T("%d"), (int)m_vtMeasureData[i].fA);
|
|
m_listMeasuData.SetItemText(iItemIndex, iColIndex++, strTxt);
|
|
|
|
strTxt.Empty();
|
|
if (0 == m_stQueryTdInfo.iSptType)
|
|
strTxt.Format(_T("%.2f"), m_vtMeasureData[i].fB);
|
|
else
|
|
strTxt.Format(_T("%d"), (int)m_vtMeasureData[i].fB);
|
|
m_listMeasuData.SetItemText(iItemIndex, iColIndex++, strTxt);
|
|
|
|
strTxt.Empty();
|
|
if (0 == m_stQueryTdInfo.iSptType)
|
|
strTxt.Format(_T("%.2f"), m_vtMeasureData[i].fM);
|
|
else
|
|
strTxt.Format(_T("%d"), (int)m_vtMeasureData[i].fM);
|
|
m_listMeasuData.SetItemText(iItemIndex, iColIndex++, strTxt);
|
|
|
|
strTxt.Empty();
|
|
if (0 == m_stQueryTdInfo.iSptType)
|
|
strTxt.Format(_T("%.2f"), m_vtMeasureData[i].fN);
|
|
else
|
|
strTxt.Format(_T("%d"), (int)m_vtMeasureData[i].fN);
|
|
m_listMeasuData.SetItemText(iItemIndex, iColIndex++, strTxt);
|
|
|
|
strTxt.Empty();
|
|
strTxt.Format(_T("%d"), pMeasuBasicRes->ucStack);
|
|
m_listMeasuData.SetItemText(iItemIndex, iColIndex++, strTxt);
|
|
|
|
strTxt.Empty();
|
|
strTxt.Format(_T("%.2f"), pMeasuBasicRes->fK);
|
|
m_listMeasuData.SetItemText(iItemIndex, iColIndex++, strTxt);
|
|
|
|
strTxt.Empty();
|
|
strTxt.Format(_T("%.2f"), pMeasuBasicRes->fV);
|
|
m_listMeasuData.SetItemText(iItemIndex, iColIndex++, strTxt);
|
|
|
|
strTxt.Empty();
|
|
strTxt.Format(_T("%.2f"), pMeasuBasicRes->fI);
|
|
m_listMeasuData.SetItemText(iItemIndex, iColIndex++, strTxt);
|
|
|
|
strTxt.Empty();
|
|
strTxt.Format(_T("%.2f"), pMeasuBasicRes->fR0);
|
|
m_listMeasuData.SetItemText(iItemIndex, iColIndex++, strTxt);
|
|
|
|
strTxt.Empty();
|
|
strTxt.Format(_T("%.2f"), pMeasuBasicRes->fSP);
|
|
m_listMeasuData.SetItemText(iItemIndex, iColIndex++, strTxt);
|
|
m_listMeasuData.SetItemData(iItemIndex, m_vtMeasureData[i].dwTsn);
|
|
}
|
|
else
|
|
{
|
|
if (LANG_ZHCN == g_iUILanguage)
|
|
AfxMessageBox(_T("插入测量数据信息失败"));
|
|
else
|
|
MessageBoxEx(NULL, _T("Failed to insert measurement data information"), STRING_MESSAGEBOXEX_TITLE, MB_OK, MAKELANGID(LANG_ENGLISH, SUBLANG_ENGLISH_US));
|
|
return EN_MEASU_PROC_DB_ERR;
|
|
}
|
|
}
|
|
|
|
return EN_MEASU_PROC_SUCCESS;
|
|
}
|
|
|
|
void CDialTimerTaskMeasu::NotifyResFunc(LPARAM lOperType, LPARAM lOperRes, LPVOID lpWnd)
|
|
{
|
|
if (NULL == lpWnd)
|
|
{
|
|
return;
|
|
}
|
|
CDialTimerTaskMeasu* pDialMeasu = (CDialTimerTaskMeasu*)lpWnd;
|
|
CString strTips = _T("");
|
|
|
|
|
|
//如果是发送失败,或者是下发任务失败的话,则直接进行提示
|
|
//按照和舒嘉讨论的结果,为了屏蔽网络的原因,现在模式改成如果没有收到相应的响应报文,就一直进行数据重发操作
|
|
//所以这段中断流程要屏蔽
|
|
/*
|
|
if (EN_RECV_SUCCESS != lOperRes && (EN_NETWORK_SEND == lOperType || EN_CTRL_MEASURE_DATA != pDialMeasu->m_ucCmd))
|
|
{
|
|
pDialMeasu->StopMeasuDataInfo(false);
|
|
strTips.Empty();
|
|
strTips.Format(_T("[%s][%d]NotifyResFunc error. OperType = %d, OperRes = %d, cmd = %d"),
|
|
MODULE_NAME, __LINE__,lOperType, lOperRes, pDialMeasu->m_ucCmd );
|
|
CFileOperTools::GetInstance()->WriteComLog(strTips);
|
|
strTips.Empty();
|
|
strTips.Format(_T("测量失败,出错代码为(%d,%d,%d)"), lOperType, lOperRes,pDialMeasu->m_ucCmd);
|
|
AfxMessageBox(strTips);
|
|
return;
|
|
}
|
|
*/
|
|
CString strLog = _T("");
|
|
|
|
if(EN_CTRL_MEASURE_DATA == pDialMeasu->m_ucCmd)
|
|
{
|
|
//如果是超时或者是数据错误的话,则运行进行重测
|
|
if (lOperRes == EN_RECV_TIMEOUT || lOperRes == EN_RECV_DATA_ERROR||lOperRes == EN_RECV_DATA_DISORDER ||
|
|
EN_CLOUND_SND_FAILED == lOperRes)
|
|
{
|
|
if (-1 == pDialMeasu->m_iRepeatSndCnt)
|
|
{
|
|
strLog.Empty();
|
|
strLog.Format(_T("[%s][%d]Is being trigger repeat measure, tripper reason = %d"), MODULE_NAME, __LINE__, lOperRes);
|
|
CFileOperTools::GetInstance()->WriteComLog(strLog);
|
|
pDialMeasu->m_iRepeatSndCnt = MAX_TIMER_REPEAT_SND_CNT+1;
|
|
}
|
|
else
|
|
{
|
|
strLog.Empty();
|
|
strLog.Format(_T("[%s][%d]measure data failed, OperType = %d,OperRes = %d,NeedRepeatCnt = %d"),
|
|
MODULE_NAME, __LINE__,lOperType,lOperRes, pDialMeasu->m_iRepeatSndCnt);
|
|
CFileOperTools::GetInstance()->WriteComLog(strLog);
|
|
}
|
|
|
|
}
|
|
else if (lOperRes == EN_RECV_SUCCESS)
|
|
{
|
|
//如果测量成功,则给下面50毫秒的时间间隔
|
|
int iRes = pDialMeasu->ProcRcvMeasuData();
|
|
if (iRes == EN_MEASU_PROC_DB_ERR || iRes == EN_MEASU_PROC_WARINNG)
|
|
{
|
|
pDialMeasu->StopMeasuDataInfo(false);
|
|
return;
|
|
}
|
|
else if (iRes == EN_MEASU_PROC_SUCCESS)
|
|
pDialMeasu->m_iRepeatSndCnt = -1;
|
|
else
|
|
if (pDialMeasu->m_iRepeatSndCnt == -1)
|
|
pDialMeasu->m_iRepeatSndCnt = MAX_TIMER_REPEAT_SND_CNT+1;
|
|
}
|
|
else
|
|
{
|
|
pDialMeasu->StopMeasuDataInfo(false);
|
|
if (LANG_ZHCN == g_iUILanguage)
|
|
{
|
|
strTips.Format(_T("Measurement data failed, error code is (%d,%d)"), lOperType, lOperRes);
|
|
AfxMessageBox(strTips);
|
|
}
|
|
else
|
|
{
|
|
strTips.Format(_T("测量数据失败,出错代码为(%d,%d)"), lOperType, lOperRes);
|
|
MessageBoxEx(NULL, strTips, STRING_MESSAGEBOXEX_TITLE, MB_OK, MAKELANGID(LANG_ENGLISH, SUBLANG_ENGLISH_US));
|
|
}
|
|
return;
|
|
}
|
|
|
|
}
|
|
//如果是点名或者设置设备参数的话,能执行到这部表示已经执行成功了,此时则进行下一步的操作
|
|
else if (EN_CTRL_ROLLCALL_CABLE == pDialMeasu->m_ucCmd || EN_CTRL_SET_TASK_PARAM == pDialMeasu->m_ucCmd ||
|
|
EN_PLC_POWER_ON == pDialMeasu->m_ucCmd)
|
|
{
|
|
//只有在成功的时候才会进行下一步的操作
|
|
if (EN_RECV_SUCCESS == lOperRes)
|
|
{
|
|
//如果是对PLC进行开关机的话,则需要判断是否开机正确
|
|
if (EN_TIMER_PROC_PLC_POWERON == pDialMeasu->m_ucProcStep)
|
|
{
|
|
int iPlcRes = COperPLC::GetInstance()->ParsePlcOperResInfo((char*)(pDialMeasu->m_ucData),pDialMeasu->m_iRecvDataLen);
|
|
if (EN_PLC_RES_SUCCESS == iPlcRes)
|
|
pDialMeasu->m_ucProcStep++;
|
|
else
|
|
{
|
|
strLog.Empty();
|
|
strLog.Format(_T("[%s][%d]excute plc cmd failed, res = %d, recv_data_len = %d"), MODULE_NAME, __LINE__, iPlcRes, pDialMeasu->m_iRecvDataLen);
|
|
CFileOperTools::GetInstance()->WriteComLog(strLog);
|
|
}
|
|
}
|
|
else
|
|
pDialMeasu->m_ucProcStep++;
|
|
}
|
|
else
|
|
{
|
|
strLog.Empty();
|
|
strLog.Format(_T("[%s][%d]excute ctrl cmd failed, proc_step = %d, res = %d"), MODULE_NAME, __LINE__, pDialMeasu->m_ucProcStep,lOperRes);
|
|
CFileOperTools::GetInstance()->WriteComLog(strLog);
|
|
}
|
|
}
|
|
else
|
|
{
|
|
strLog.Empty();
|
|
strLog.Format(_T("[%s][%d]Unknow ctrl command(%d)"), MODULE_NAME, __LINE__, pDialMeasu->m_ucCmd);
|
|
CFileOperTools::GetInstance()->WriteComLog(strLog);
|
|
}
|
|
pDialMeasu->m_bIsSigMeasuring = false;
|
|
}
|
|
|
|
int CDialTimerTaskMeasu::GetNeedMeasuData(char* pData,int &iLen, int iMaxLen)
|
|
{
|
|
iLen = 0;
|
|
m_vtMeasureData.clear();
|
|
if (m_TaskdDBOper.QueryNextTdBasicData(m_vtMeasureData) < 0)
|
|
{
|
|
return -1;
|
|
}
|
|
|
|
int iNum = m_vtMeasureData.size();
|
|
if (iNum > 0)
|
|
{
|
|
if (iMaxLen < iNum * sizeof(STSigSndDataInfo))
|
|
{
|
|
if (LANG_ZHCN == g_iUILanguage)
|
|
AfxMessageBox(_T("测量数据的长度过大"));
|
|
else
|
|
MessageBoxEx(NULL, _T("The length of measure data is overlength"), STRING_MESSAGEBOXEX_TITLE, MB_OK, MAKELANGID(LANG_ENGLISH, SUBLANG_ENGLISH_US));
|
|
return -1;
|
|
}
|
|
memcpy(pData, m_stQueryTdInfo.ucTaskID, sizeof(m_stQueryTdInfo.ucTaskID));
|
|
pData[sizeof(m_stQueryTdInfo.ucTaskID)] = m_vtMeasureData.size();
|
|
//pData[0]= m_vtMeasureData.size();
|
|
for (int i = 0; i < m_vtMeasureData.size(); i++)
|
|
{
|
|
STSigSndDataInfo stSigData;//转网络序
|
|
memcpy(&stSigData, &m_vtMeasureData[i], sizeof(STSigSndDataInfo));
|
|
stSigData.dwTsn = htonl(stSigData.dwTsn);
|
|
stSigData.fA = tcp_htonf(stSigData.fA);
|
|
stSigData.fB = tcp_htonf(stSigData.fB);
|
|
stSigData.fM = tcp_htonf(stSigData.fM);
|
|
stSigData.fN = tcp_htonf(stSigData.fN);
|
|
stSigData.fK = tcp_htonf(stSigData.fK);
|
|
|
|
memcpy(pData + 1 + sizeof(m_stQueryTdInfo.ucTaskID) + i*sizeof(STSigSndDataInfo), &stSigData, sizeof(STSigSndDataInfo));
|
|
}
|
|
iLen = 1 + sizeof(m_stQueryTdInfo.ucTaskID)+iNum*sizeof(STSigSndDataInfo);
|
|
}
|
|
return 1;
|
|
}
|
|
|
|
|
|
void CDialTimerTaskMeasu::StopMeasuDataInfo(bool bIsNormalExit)
|
|
{
|
|
int iID = 0;
|
|
if (m_bIsOpenTbData)
|
|
{
|
|
m_TaskdDBOper.CloseTdData();
|
|
m_bIsOpenTbData = false;
|
|
}
|
|
m_bIsSigMeasuring = false;
|
|
m_iRepeatSndCnt = -1;
|
|
if (bIsNormalExit)
|
|
m_ucProcStep = EN_TIMER_PROC_MEASU_FIN;
|
|
else
|
|
m_ucProcStep = EN_TIMER_PROC_MEASU_TRMI;
|
|
}
|
|
|
|
void CDialTimerTaskMeasu::ClearRecvBuffer()
|
|
{
|
|
memset(m_ucData, 0, sizeof(m_ucData));
|
|
m_iRecvDataLen = 0;
|
|
}
|
|
|
|
bool CDialTimerTaskMeasu::OperPLC(BYTE ucCmd, CString strPlcID, bool bIsShowErrSyn)
|
|
{
|
|
char chMsg[300]={0};
|
|
int iLen = 0;
|
|
COperPLC::GetInstance()->GetPlcCmdInfo(ucCmd, chMsg, iLen, 300);
|
|
if (iLen < 1)
|
|
{
|
|
return false;
|
|
}
|
|
DWORD dwDevID = atoi(strPlcID);
|
|
CString strErr = _T("");
|
|
CAutoLock autoLock(theApp.m_NetWorkOper.GetNetCriticalSection());
|
|
if (!theApp.m_NetWorkOper.SendCtrlMsgDirect(1,dwDevID, EN_DEV_PLC, chMsg, iLen))
|
|
{
|
|
if (bIsShowErrSyn)
|
|
{
|
|
if (LANG_ZHCN == g_iUILanguage)
|
|
AfxMessageBox(_T("同步失败"));
|
|
else
|
|
MessageBoxEx(NULL, _T("Synchronization failure"), STRING_MESSAGEBOXEX_TITLE, MB_OK, MAKELANGID(LANG_ENGLISH, SUBLANG_ENGLISH_US));
|
|
}
|
|
else
|
|
{
|
|
strErr.Empty();
|
|
strErr.Format(_T("[CDialTimerTaskMeasu][%d]send oper ctrl cmd(%d) failed."),__LINE__, ucCmd);
|
|
CFileOperTools::GetInstance()->WriteComLog(strErr);
|
|
}
|
|
|
|
return false;
|
|
}
|
|
Sleep(300);
|
|
if (EN_RECV_SUCCESS != theApp.m_NetWorkOper.RecvMsgDirect(chMsg, &iLen, 300, 90))
|
|
{
|
|
if (bIsShowErrSyn)
|
|
{
|
|
if (LANG_ZHCN == g_iUILanguage)
|
|
AfxMessageBox(_T("接收数据失败"));
|
|
else
|
|
MessageBoxEx(NULL, _T("Data received failed"), STRING_MESSAGEBOXEX_TITLE, MB_OK, MAKELANGID(LANG_ENGLISH, SUBLANG_ENGLISH_US));
|
|
}
|
|
else
|
|
{
|
|
strErr.Empty();
|
|
strErr.Format(_T("[CDialTimerTaskMeasu][%d]recv oper ctrl cmd(%d) response failed."),__LINE__, ucCmd);
|
|
CFileOperTools::GetInstance()->WriteComLog(strErr);
|
|
}
|
|
|
|
return false;
|
|
}
|
|
if (iLen != sizeof(STRemPlcDataInfo))
|
|
{
|
|
if (bIsShowErrSyn)
|
|
{
|
|
if (LANG_ZHCN == g_iUILanguage)
|
|
AfxMessageBox(_T("长度校验失败"));
|
|
else
|
|
MessageBoxEx(NULL, _T("Length check failed"), STRING_MESSAGEBOXEX_TITLE, MB_OK, MAKELANGID(LANG_ENGLISH, SUBLANG_ENGLISH_US));
|
|
}
|
|
else
|
|
{
|
|
strErr.Empty();
|
|
strErr.Format(_T("[CDialTimerTaskMeasu][%d]recv oper ctrl cmd(%d) error,check format failed."),__LINE__, ucCmd);
|
|
CFileOperTools::GetInstance()->WriteComLog(strErr);
|
|
}
|
|
|
|
return false;
|
|
}
|
|
STRemPlcDataInfo* pPlcInfo = (STRemPlcDataInfo*)chMsg;
|
|
if ( 1== pPlcInfo->ucResult )
|
|
return true;
|
|
else
|
|
return false;
|
|
}
|
|
|
|
bool CDialTimerTaskMeasu::GetRollCallData(char* pData, int& iLen, int iMaxLen)
|
|
{
|
|
memset(pData, 0, iMaxLen);
|
|
iLen = 0;
|
|
return true;
|
|
}
|
|
extern float tcp_htonf(float f);
|
|
bool CDialTimerTaskMeasu::GetCfgTaskData(DWORD dwTdID,char* pData, int& iLen, int iMaxLen)
|
|
{
|
|
CString strLog = _T("");
|
|
iLen = 0;
|
|
if (m_TaskdDBOper.QueryTdBasicInfo(dwTdID, &m_stQueryTdInfo))
|
|
{
|
|
STMeasuTaskParam stTaskParam;
|
|
memset(&stTaskParam, 0, sizeof(STMeasuTaskParam));
|
|
stTaskParam.ucTxPeriod = m_stQueryTdInfo.iTestPeriod;
|
|
stTaskParam.ucTestType = m_stQueryTdInfo.iTestType;
|
|
stTaskParam.ucSptType = m_stQueryTdInfo.iSptType;
|
|
stTaskParam.ucCableLayout = m_stQueryTdInfo.iCableLayout;
|
|
stTaskParam.ucStacking = m_stQueryTdInfo.ucStack;
|
|
stTaskParam.iSAInterval = htonl(m_stQueryTdInfo.iSAInterval);
|
|
stTaskParam.ucArrayType = m_stQueryTdInfo.iAR;
|
|
stTaskParam.fElecSpace = tcp_htonf(m_stQueryTdInfo.fXElecDistance);
|
|
stTaskParam.ucOrgFlg = m_stQueryTdInfo.ucOrgFlg;
|
|
memcpy(stTaskParam.ucTaskID, m_stQueryTdInfo.ucTaskID, sizeof(stTaskParam.ucTaskID));
|
|
iLen = sizeof(STMeasuTaskParam);
|
|
memcpy(pData, &stTaskParam, iLen);
|
|
}
|
|
else
|
|
{
|
|
strLog.Format(_T("[%s][%d]Query task information failed. taskid = %d"), dwTdID);
|
|
CFileOperTools::GetInstance()->WriteComLog(strLog);
|
|
if (LANG_ZHCN == g_iUILanguage)
|
|
AfxMessageBox(_T("查询任务信息失败"));
|
|
else
|
|
MessageBoxEx(NULL, _T("Query task information failed"), STRING_MESSAGEBOXEX_TITLE, MB_OK, MAKELANGID(LANG_ENGLISH, SUBLANG_ENGLISH_US));
|
|
return false;
|
|
}
|
|
return true;
|
|
|
|
}
|
|
|
|
void CDialTimerTaskMeasu::SetBtnStatus(BYTE ucStatus)
|
|
{
|
|
switch (ucStatus)
|
|
{
|
|
case EN_TIMER_PROC_ROLLCALL:
|
|
case EN_TIMER_PROC_CFG_TASK:
|
|
case EN_TIMER_PROC_MEASU_DATA:
|
|
GetDlgItem(IDC_BUTTON_TIMER_MRASU)->EnableWindow(FALSE);
|
|
GetDlgItem(IDC_BUTTON_MRASU_SUSPEND)->EnableWindow(TRUE);
|
|
GetDlgItem(IDC_BUTTON_MRASU_SUSPEND)->SetWindowText("Suspend");
|
|
break;
|
|
case EN_TIMER_PROC_MEASU_SUSPEND:
|
|
GetDlgItem(IDC_BUTTON_TIMER_MRASU)->EnableWindow(FALSE);
|
|
GetDlgItem(IDC_BUTTON_MRASU_SUSPEND)->EnableWindow(TRUE);
|
|
GetDlgItem(IDC_BUTTON_MRASU_SUSPEND)->SetWindowText("Continue");
|
|
break;
|
|
default:
|
|
GetDlgItem(IDC_BUTTON_TIMER_MRASU)->EnableWindow(FALSE);
|
|
GetDlgItem(IDC_BUTTON_MRASU_SUSPEND)->EnableWindow(FALSE);
|
|
GetDlgItem(IDC_BUTTON_MRASU_SUSPEND)->SetWindowText("Suspend");
|
|
break;
|
|
}
|
|
|
|
}
|
|
|
|
bool CDialTimerTaskMeasu::StartTimerTask(const STTimerTask* pTimerTask)
|
|
{
|
|
//首先开机
|
|
char chSndBuf[500] = {0};
|
|
int iSndLen = 0, iTimeout = 0, iMaxRcvLen = 0;
|
|
// BYTE ucCmd;
|
|
m_ucProcStep = EN_TIMER_PROC_PLC_POWERON;
|
|
// m_ucProcStep =EN_TIMER_PROC_ROLLCALL;
|
|
m_iRepeatSndCnt = -1;
|
|
|
|
STRespDataInfo stRspData;
|
|
STSendDataInfo stSendData;
|
|
CString strLog;
|
|
|
|
if (m_bIsOpenTbData)
|
|
{
|
|
m_TaskdDBOper.CloseTdData();
|
|
m_bIsOpenTbData = false;
|
|
}
|
|
GetDlgItem(IDC_STATIC_TASK_NAME)->SetWindowText(pTimerTask->strTaskName);
|
|
strLog.Empty();
|
|
strLog.Format(_T("[%s][%d]Is ready to excute timer task(%s)"),MODULE_NAME, __LINE__, pTimerTask->strTaskName);
|
|
CFileOperTools::GetInstance()->WriteComLog(strLog);
|
|
// m_bIsSigMeasuring =
|
|
|
|
//filled current test date and time to task by quyx 20180419
|
|
_CommandPtr pCmdUpd = NULL;
|
|
CString szTDate = _T("");
|
|
CString szTTime = _T("");
|
|
CString szSql = _T("");
|
|
DWORD dwID = DWORD(pTimerTask->uiTaskID);
|
|
|
|
szTDate.Empty();
|
|
szTDate.Format(_T("%04d-%02d-%02d"),g_sysCurTime.wYear, g_sysCurTime.wMonth, g_sysCurTime.wDay);
|
|
szTTime.Empty();
|
|
szTTime.Format(_T("%02d:%02d:%02d"),g_sysCurTime.wHour, g_sysCurTime.wMinute, g_sysCurTime.wSecond);
|
|
|
|
pCmdUpd.CreateInstance(_uuidof(Command));
|
|
pCmdUpd->ActiveConnection = theApp.m_pConnection;
|
|
try
|
|
{
|
|
if ((szTDate.GetLength() != (int)VAL_ZERO) && (szTTime.GetLength() != (int)VAL_ZERO))
|
|
{
|
|
szSql.Empty();
|
|
szSql.Format(_T("update td set Tdate = '%s',Ttime = '%s' where ID = %d"), szTDate, szTTime,dwID);
|
|
theApp.m_pConnection->BeginTrans();
|
|
pCmdUpd->CommandText = szSql.AllocSysString();
|
|
pCmdUpd->Execute(NULL, NULL, adCmdText);
|
|
theApp.m_pConnection->CommitTrans();
|
|
}
|
|
}
|
|
catch (_com_error e)
|
|
{
|
|
theApp.m_pConnection->RollbackTrans();
|
|
AfxMessageBox(e.Description());
|
|
return -1;
|
|
}
|
|
//end filled current test date and time to task by quyx 20180419
|
|
|
|
while(m_bIsRunning)
|
|
{
|
|
if (m_bIsSigMeasuring || m_bIsSuspend)
|
|
{
|
|
Sleep(30);
|
|
continue;
|
|
}
|
|
if (EN_TIMER_PROC_PLC_POWERON == m_ucProcStep)
|
|
{
|
|
m_ucCmd = EN_PLC_POWER_ON;
|
|
COperPLC::GetInstance()->GetPlcCmdInfo(m_ucCmd, chSndBuf, iSndLen, 500);
|
|
if (iSndLen < 1)
|
|
{
|
|
if (LANG_ZHCN == g_iUILanguage)
|
|
AfxMessageBox(_T("PLC开机失败"));
|
|
else
|
|
MessageBoxEx(NULL, _T("PLC power on failed."), STRING_MESSAGEBOXEX_TITLE, MB_OK, MAKELANGID(LANG_ENGLISH, SUBLANG_ENGLISH_US));
|
|
return false;
|
|
}
|
|
iMaxRcvLen = 200;
|
|
iTimeout = 3000;
|
|
|
|
}
|
|
else if (EN_TIMER_PROC_ROLLCALL == m_ucProcStep)
|
|
{
|
|
m_ucCmd = EN_CTRL_ROLLCALL_CABLE;
|
|
GetRollCallData(chSndBuf, iSndLen, 500);
|
|
iMaxRcvLen = 200;
|
|
iTimeout = 40000;
|
|
}
|
|
else if (EN_TIMER_PROC_CFG_TASK == m_ucProcStep)
|
|
{
|
|
m_ucCmd = EN_CTRL_SET_TASK_PARAM;
|
|
GetCfgTaskData(pTimerTask->uiTaskID,chSndBuf, iSndLen, 500);
|
|
iMaxRcvLen = MAX_RECV_MEASURE;
|
|
iTimeout = 12000;
|
|
}
|
|
else if (EN_TIMER_PROC_MEASU_DATA == m_ucProcStep)
|
|
{
|
|
if (!m_bIsOpenTbData)
|
|
{
|
|
if (!m_TaskdDBOper.OpenTdData(pTimerTask->uiTaskID,m_stQueryTdInfo.iSptType,1, theApp.m_ucMaxChannel))
|
|
{
|
|
if (LANG_ZHCN == g_iUILanguage)
|
|
AfxMessageBox(_T("打开数据表失败"));
|
|
else
|
|
MessageBoxEx(NULL, _T("Failed to open data table"), STRING_MESSAGEBOXEX_TITLE, MB_OK, MAKELANGID(LANG_ENGLISH, SUBLANG_ENGLISH_US));
|
|
return false;
|
|
}
|
|
m_bIsOpenTbData = true;
|
|
}
|
|
|
|
m_ucCmd = EN_CTRL_MEASURE_DATA;
|
|
iMaxRcvLen = MAX_RECV_MEASURE;
|
|
//test为了屏蔽网络中断的影响,这里将单个点的最大超时时间改为1分钟
|
|
//那么最多9万重发机会的话,
|
|
//激点数据后面再修改
|
|
iTimeout = 60000;
|
|
if (m_iRepeatSndCnt <= 0)
|
|
{
|
|
//如果没有打开数据表的话,则进行打开数据表
|
|
memset(chSndBuf, 0, sizeof(chSndBuf));
|
|
iSndLen = 0;
|
|
m_iRepeatSndCnt = -1;//初始状态
|
|
int iRes = GetNeedMeasuData(chSndBuf, iSndLen,500);
|
|
if (0 == iSndLen)
|
|
{
|
|
if (iRes > 0)
|
|
{
|
|
StopMeasuDataInfo();
|
|
SetBtnStatus(m_ucProcStep);
|
|
return true;
|
|
}
|
|
else
|
|
{
|
|
StopMeasuDataInfo(false);
|
|
SetBtnStatus(m_ucProcStep);
|
|
return false;
|
|
}
|
|
}
|
|
|
|
}
|
|
else
|
|
{
|
|
strLog.Empty();
|
|
strLog.Format(_T("[%s][%d]Is being repeat measure, reverse repeat cnt = %d"), MODULE_NAME, __LINE__, --m_iRepeatSndCnt);
|
|
CFileOperTools::GetInstance()->WriteComLog(strLog);
|
|
}
|
|
}
|
|
else
|
|
{
|
|
strLog.Empty();
|
|
strLog.Format(_T("[%s][%d]Unknow timer proc step(%d)"), MODULE_NAME, __LINE__,m_ucProcStep);
|
|
CFileOperTools::GetInstance()->WriteComLog(strLog);
|
|
SetBtnStatus(m_ucProcStep);
|
|
return (m_ucProcStep == EN_TIMER_PROC_MEASU_FIN) ? true : false;
|
|
}
|
|
|
|
stSendData.pData = chSndBuf;
|
|
stSendData.wDataLen = iSndLen;
|
|
if (EN_TIMER_PROC_PLC_POWERON == m_ucProcStep)
|
|
{
|
|
stSendData.ucDstType = EN_DEV_PLC;
|
|
stSendData.uiDevID = atoi(pTimerTask->strPlcID);
|
|
}
|
|
else
|
|
{
|
|
stSendData.ucDstType = EN_DEV_GD10;
|
|
stSendData.uiDevID = m_uiDevID;
|
|
}
|
|
|
|
|
|
ClearRecvBuffer();
|
|
stRspData.pData = (char*)m_ucData;
|
|
stRspData.pRecvLen = &m_iRecvDataLen;
|
|
stRspData.iMaxRcvLen = iMaxRcvLen;
|
|
stRspData.iTimeout = iTimeout;
|
|
|
|
|
|
if (false == theApp.m_NetWorkOper.TransferOper(m_ucCmd, &stSendData, true, &stRspData, NotifyResFunc, this))
|
|
{
|
|
StopMeasuDataInfo(false);
|
|
Sleep(30);
|
|
continue;
|
|
}
|
|
m_bIsSigMeasuring = true;
|
|
}
|
|
|
|
}
|
|
|
|
int CDialTimerTaskMeasu::CompareTdTimer(const SYSTEMTIME &curTime, CString strTdTimer)
|
|
{
|
|
CString str1 = _T("");
|
|
strTdTimer.TrimLeft();
|
|
strTdTimer.TrimRight();
|
|
str1.Format(_T("%04d-%02d-%02d %02d:%02d"),curTime.wYear, curTime.wMonth, curTime.wDay,curTime.wHour,curTime.wMinute);
|
|
int nYear=0, nMonth = 0, nDay = 0, nHour = 0, nMinute = 0, nSecond = 0;
|
|
if (-1 == strTdTimer.Find(_T("-")))
|
|
_stscanf(strTdTimer, _T("%d/%d/%d %d:%d:%d"), &nYear, &nMonth, &nDay, &nHour, &nMinute, &nSecond);
|
|
else
|
|
_stscanf(strTdTimer, _T("%d-%d-%d %d:%d:%d"), &nYear, &nMonth, &nDay, &nHour, &nMinute, &nSecond);
|
|
CString strTemp = strTdTimer;
|
|
strTdTimer.Empty();
|
|
strTdTimer.Format(_T("%04d-%02d-%02d %02d:%02d"), nYear, nMonth, nDay, nHour,nMinute);
|
|
int iRes = strcmp(str1, strTdTimer);
|
|
if (iRes > 0)
|
|
{
|
|
CString strLog = _T("");
|
|
strLog.Format(_T("[%s][%d]timer task timeout. Sys_time = %s, Task_time = %s,Task_org=%s"),MODULE_NAME, __LINE__,str1, strTdTimer,strTemp);
|
|
CFileOperTools::GetInstance()->WriteComLog(strLog);
|
|
}
|
|
|
|
return iRes;
|
|
}
|
|
|
|
UINT CDialTimerTaskMeasu::StartMeasuData(LPVOID pInfo)
|
|
{
|
|
CDialTimerTaskMeasu* pMeasuData = (CDialTimerTaskMeasu*)pInfo;
|
|
|
|
char chSndBuf[500] = {0};
|
|
std::vector<STTimerTask> vtTimerTd;
|
|
pMeasuData->m_TaskdDBOper.QueryTimerTaskValiad(vtTimerTd, g_sysCurTime);
|
|
if (vtTimerTd.size() < 1)
|
|
{
|
|
if (LANG_ZHCN == g_iUILanguage)
|
|
AfxMessageBox(_T("没有找到有效的定时任务"));
|
|
else
|
|
MessageBoxEx(NULL, _T("Can not found valid timer task"), STRING_MESSAGEBOXEX_TITLE, MB_OK, MAKELANGID(LANG_ENGLISH, SUBLANG_ENGLISH_US));
|
|
return 0;
|
|
}
|
|
pMeasuData->m_bIsThreadFinshed = false;
|
|
int iSendLen = 0;
|
|
// STTimerTask timerTd = vtTimerTd[0];
|
|
CString strErr = _T("");
|
|
while(pMeasuData->m_bIsRunning)
|
|
{
|
|
if (vtTimerTd.size() < 1)
|
|
{
|
|
if (LANG_ZHCN == g_iUILanguage)
|
|
AfxMessageBox(_T("执行完成"));
|
|
else
|
|
MessageBoxEx(NULL, _T("Excute complete"), STRING_MESSAGEBOXEX_TITLE, MB_OK, MAKELANGID(LANG_ENGLISH, SUBLANG_ENGLISH_US));
|
|
break;
|
|
}
|
|
int iRes = pMeasuData->CompareTdTimer(g_sysCurTime, vtTimerTd[0].strRunTime);
|
|
if (iRes < 0)
|
|
{
|
|
Sleep(1000);
|
|
continue;
|
|
}
|
|
|
|
else if (iRes > 0)
|
|
{
|
|
pMeasuData->m_TaskdDBOper.DeleteTimerTask(vtTimerTd[0].uiTaskID);
|
|
vtTimerTd.erase(vtTimerTd.begin());
|
|
continue;
|
|
}
|
|
else
|
|
{
|
|
bool bRes = pMeasuData->StartTimerTask(&(vtTimerTd[0]));
|
|
/////////////////////////////////////////////////////////////////////////
|
|
// char chSndBuf[500] = {0};
|
|
// int iSndLen = 0;
|
|
if (false == pMeasuData->OperPLC(EN_PLC_POWER_OFF, vtTimerTd[0].strPlcID,false))
|
|
{
|
|
CString strErr = _T("");
|
|
strErr.Format(_T("[CDialTimerTaskMeasu][%d]oper timer task power off cmd failed."),__LINE__);
|
|
CFileOperTools::GetInstance()->WriteComLog(strErr);
|
|
}
|
|
|
|
// COperPLC::GetInstance()->GetPlcCmdInfo(EN_PLC_POWER_OFF, chSndBuf, iSendLen, 500);
|
|
|
|
//////////////////////////////////////////////////////////////////////////
|
|
pMeasuData->m_TaskdDBOper.DeleteTimerTask(vtTimerTd[0].uiTaskID);
|
|
vtTimerTd.erase(vtTimerTd.begin());
|
|
if (!bRes)
|
|
{
|
|
if (LANG_ZHCN == g_iUILanguage)
|
|
AfxMessageBox(_T("执行定时任务错误"));
|
|
else
|
|
MessageBoxEx(NULL, _T("Excute timer task error"), STRING_MESSAGEBOXEX_TITLE, MB_OK, MAKELANGID(LANG_ENGLISH, SUBLANG_ENGLISH_US));
|
|
break;
|
|
}
|
|
|
|
}
|
|
|
|
}
|
|
pMeasuData->m_bIsThreadFinshed = true;
|
|
return 1;
|
|
|
|
|
|
}
|
|
|
|
BOOL CDialTimerTaskMeasu::OnInitDialog()
|
|
{
|
|
CDialog::OnInitDialog();
|
|
|
|
// TODO: Add extra initialization here
|
|
CString strColTitle;
|
|
|
|
int iColIndex = 0;
|
|
|
|
m_listMeasuData.SetExtendedStyle(LVS_EX_FULLROWSELECT | LVS_EX_HEADERDRAGDROP
|
|
| LVS_EX_ONECLICKACTIVATE | LVS_EX_GRIDLINES);
|
|
|
|
m_listMeasuData.InsertColumn(iColIndex++, _T("ID"),LVCFMT_LEFT,50);
|
|
|
|
// strColTitle.Empty();
|
|
// strColTitle.LoadString(IDS_DB_SCRIPT_C1);
|
|
m_listMeasuData.InsertColumn(iColIndex++, _T("A"), LVCFMT_CENTER, 50);
|
|
|
|
// strColTitle.Empty();
|
|
// strColTitle.LoadString(IDS_DB_SCRIPT_C2);
|
|
m_listMeasuData.InsertColumn(iColIndex++, _T("B"), LVCFMT_CENTER, 50);
|
|
|
|
// strColTitle.Empty();
|
|
// strColTitle.LoadString(IDS_DB_SCRIPT_P1);
|
|
m_listMeasuData.InsertColumn(iColIndex++, _T("M"), LVCFMT_CENTER, 50);
|
|
|
|
// strColTitle.Empty();
|
|
// strColTitle.LoadString(IDS_DB_SCRIPT_P2);
|
|
m_listMeasuData.InsertColumn(iColIndex++, _T("N"), LVCFMT_CENTER, 50);
|
|
|
|
// strColTitle.Empty();
|
|
// strColTitle.LoadString(IDS_DB_SCRIPT_N);
|
|
m_listMeasuData.InsertColumn(iColIndex++, _T("Stack"), LVCFMT_CENTER, 50);
|
|
|
|
// strColTitle.Empty();
|
|
// strColTitle.LoadString(IDS_DB_SCRIPT_K);
|
|
m_listMeasuData.InsertColumn(iColIndex++, _T("K"), LVCFMT_CENTER, 90);
|
|
|
|
// strColTitle.Empty();
|
|
// strColTitle.LoadString(IDS_MEASU_TD_V);
|
|
m_listMeasuData.InsertColumn(iColIndex++, _T("V(mV)"), LVCFMT_CENTER, 95);
|
|
|
|
// strColTitle.Empty();
|
|
// strColTitle.LoadString(IDS_MEASU_TD_I);
|
|
m_listMeasuData.InsertColumn(iColIndex++, _T("I(mA)"), LVCFMT_CENTER, 95);
|
|
|
|
// strColTitle.Empty();
|
|
// strColTitle.LoadString(IDS_MEASU_TD_R0);
|
|
m_listMeasuData.InsertColumn(iColIndex++, _T("R0(Ohm*m)"), LVCFMT_CENTER, 95);
|
|
|
|
// strColTitle.Empty();
|
|
// strColTitle.LoadString(IDS_MEASU_TD_SP);
|
|
m_listMeasuData.InsertColumn(iColIndex++, _T("SP(mV)"), LVCFMT_CENTER, 95);
|
|
|
|
GetDlgItem(IDC_BUTTON_MRASU_SUSPEND)->ShowWindow(SW_HIDE);
|
|
return TRUE; // return TRUE unless you set the focus to a control
|
|
// EXCEPTION: OCX Property Pages should return FALSE
|
|
}
|
|
|
|
void CDialTimerTaskMeasu::OnCancel()
|
|
{
|
|
// TODO: Add extra cleanup here
|
|
if (NULL != m_pThread)
|
|
{
|
|
int nRet = 0;
|
|
if (LANG_ZHCN == g_iUILanguage)
|
|
nRet = AfxMessageBox(_T("是否确定关闭?"), MB_YESNO | MB_ICONQUESTION);
|
|
else
|
|
nRet = MessageBoxEx(NULL, _T("Are you sure to close?"), STRING_MESSAGEBOXEX_TITLE, MB_YESNO, MAKELANGID(LANG_ENGLISH, SUBLANG_ENGLISH_US));
|
|
if (IDYES != nRet)
|
|
return;
|
|
}
|
|
ThreadJoin();
|
|
CDialog::OnCancel();
|
|
}
|
|
|
|
void CDialTimerTaskMeasu::OnButtonTimerCfg()
|
|
{
|
|
// TODO: Add your control notification handler code here
|
|
CDialTimerTask dialTimerTd;
|
|
dialTimerTd.m_dataOper.m_uiDevID = m_uiDevID;
|
|
dialTimerTd.DoModal();
|
|
|
|
}
|